EGIS
EGIS 500A Sealed Contactor with Auxiliary Contacts 12/24V
Pickup available at Mercury Yacht Harbour
Usually ready in 2-4 days
Description
This hermetically sealed 500A contactor provides reliable remote switching of high-current engine and auxiliary loads, sealing out dust and moisture for dependable operation in harsh marine and mobile environments. By replacing manual switches mounted close to the battery, it eliminates long, heavy cable runs, reducing both installation cost and weight. A high contact voltage rating allows the unit to be controlled from a 12 or 24 Vdc signal while switching higher voltages up to 48V and beyond, and ignition protection to ISO-8846 and UL 1500 makes it safe to install inside closed compartments where explosive gases may be present.
Built for the engine compartment, the contactor uses high-temperature materials throughout and is secured with 18-8 stainless steel self-locking hardware and reinforced mounting holes for a secure, straightforward installation. Unlike the standard model, this version adds auxiliary contacts that give positive confirmation of the relay on or off state, supporting remote status indication so the system always knows whether the load is live. The result is a bullet-proof switching solution that combines high interrupt capability with the durability demanded by continuous engine-compartment use.
PRODUCT DETAILS
- Hermetically sealed against dust and moisture for harsh environments
- 500A continuous current rating
- Wide 9 to 36 V DC control voltage for 12 or 24V systems
- High interrupt capability up to 1,500 A at 14 Vdc
- Auxiliary contacts for remote on/off status indication
- Ignition protected to ISO-8846 and UL 1500 for closed compartments
- 18-8 stainless steel self-locking hardware and IP67/IP69K sealing
- 1 x EGIS 500A sealed contactor with auxiliary contacts
- 18-8 stainless steel self-locking mounting hardware
No compatible transducers listed for this product.
No spares or accessories listed for this product.
No compatible products found.
Electrical
| Continuous Current | 500 A |
| Operating Control Voltage | 9-36 V DC |
| Max Interrupt Current | 1,500 A at 14 Vdc |
| Electrical Endurance | 6,000 cycles at 250A / 450V; 100,000 cycles at 250A / 14V |
| Auxiliary Contacts | Yes, for remote status indication |
Mechanical
| Ingress Protection | IP67 / IP69K |
| Ignition Protection | ISO-8846 / UL 1500 |
| Min Operating Temperature | -40 C |
| Max Operating Temperature | 85 C |
| Hardware | 18-8 stainless steel self-locking |
No videos available for this product.