The Victron MultiPlus-II 48/5000/70 is a 230 V multifunctional inverter/charger for professional marine, vehicle and off-grid systems built around a 48 V battery bank. It combines a strong 5000 VA pure sine wave inverter with a 70 A battery charger in a single enclosure, supplying clean 230 VAC mains power from the batteries. The 48 V architecture keeps DC currents low, simplifying cabling on larger installations.
PowerAssist is the standout capability. When shore or generator power is limited, the MultiPlus-II adds energy from the battery to cover load peaks, preventing the source from overloading while still using any spare capacity to recharge. The integrated transfer switch returns loads to the inverter in under 20 milliseconds during a grid failure, so sensitive electronics keep running without disruption.
Designed for energy storage and solar self-consumption, the MultiPlus-II works with both MPPT solar chargers and grid-tie inverters, has built-in anti-islanding and a long list of grid-code approvals, and can be paralleled or three-phased for higher output. An external current sensor extends PowerControl and PowerAssist up to 100 A. Setup, monitoring and control run through VictronConnect, a GX device and the free VRM portal.
PRODUCT DETAILS
- 5000 VA pure sine wave inverter with a 230 VAC, 50 Hz output for 48 V battery banks
- Powerful 70 A multi-stage battery charger for fast recharging
- PowerAssist boosts limited shore or generator supply with battery power to avoid overload
- PowerControl limits AC input current to protect the grid or generator
- Uninterrupted transfer to inverter in under 20 milliseconds during a power failure
- Built-in anti-islanding with extensive ESS grid-code approvals
- Parallel and three-phase capable, up to six units for higher output
- Monitoring and configuration via VictronConnect, GX devices and the free VRM portal
No compatible transducers listed for this product.
No spares or accessories listed for this product.
No compatible products found.
Key specifications
| System voltage | 48 V |
| Continuous output power | 5000 VA |
| Continuous output power at 25°C | 4000 W |
| Peak power | 9000 W |
| Maximum charge current | 70 A |
| Transfer switch | 50 A |
AC inputs
| AC input voltage range | 187 to 265 VAC |
| AC input frequency | 45 to 65 Hz |
| Maximum feed-through current | 50 A |
Inverter
| DC input voltage range | 38 to 66 V |
| Output voltage / frequency | 230 VAC ±2%, 50 Hz ±0.1% |
| Cont. output power at 25°C (VA) | 5000 VA |
| Cont. output power at 25°C (W) | 4000 W |
| Cont. output power at 40°C (W) | 3700 W |
| Cont. output power at 65°C (W) | 3000 W |
| Peak power | 9000 W |
| Maximum efficiency | 96% |
| Maximum apparent feed-in power | 5000 VA |
| Zero load power | 18 W |
| Zero load power in Search mode | 2 W |
| Zero load power in AES mode | 12 W |
Charger
| Charge voltage 'absorption' | 57.6 V |
| Charge voltage 'float' | 55.2 V |
| Storage mode | 52.8 V |
| Maximum charge current | 70 A |
| Battery temperature sensor | Not included with 48 V models (order ASS000001000) |
Connectivity & control
| VE.Bus communication port | For parallel and three-phase operation, remote monitoring and system integration |
| General purpose comms port | Yes, 2x |
| Programmable relay | Yes |
| Auxiliary output | 50 A |
| Remote on/off | Yes |
| External AC current sensor (optional) | 100 A |
Protection
| Protection | Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 VAC on inverter output, input voltage ripple too high |
Environmental
| Operating temperature range | -40 to +65°C (fan-assisted cooling) |
| Humidity (non-condensing) | Max 95% |
| Maximum altitude | 2000 m |
Physical
| Material & colour | Steel, blue RAL 5012 |
| Protection category | IP22 |
| Battery connection | M8 bolts |
| 230 VAC connection | Screw terminals 13 mm² (6 AWG) |
| Weight | 30 kg |
| Dimensions (h x w x d) | 607 x 330 x 149 mm |
Conformance
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
| Emission / Immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 |