Victron
Victron Phoenix Inverter 48/375 VE.Direct 120V (NEMA 5-15R)
Pickup available at Mercury Yacht Harbour
Usually ready in 2-4 days
Description
The Victron Phoenix Inverter 48/375 VE.Direct (120V) converts 48V battery power into a clean 120V, 60 Hz pure sine wave AC supply, ideal for running sensitive electronics aboard a boat or in an off-grid installation in 120V territories. Built around a proven full-bridge and toroidal transformer topology, it delivers dependable power with the low standby draw that suits long unattended use.
An integrated VE.Direct port lets you monitor and configure the inverter from a phone, tablet or computer using a VE.Direct to USB cable or a Bluetooth Smart dongle (sold separately). ECO mode drops the unit into standby when no significant load is present, cutting idle consumption to conserve the battery bank. This model fits a NEMA 5-15R outlet with GFCI protection and is UL 458 listed, and includes a two-pole remote on/off connector and high start-up power for demanding loads.
PRODUCT DETAILS
- Pure sine wave output for safe operation of sensitive electronics
- 375 VA continuous power with 700 W peak for high start-up loads
- 120 VAC, 60 Hz output for 120V territories
- VE.Direct communication port for monitoring and full configuration
- ECO mode reduces standby consumption to conserve the battery
- High efficiency up to 90% with low zero-load power draw
- NEMA 5-15R outlet with GFCI protection, UL 458 listed
- Remote on/off via two-pole connector, fan-assisted cooling
No compatible transducers listed for this product.
Key specifications
| Continuous power (VA) | 375 VA |
| Continuous power (W) | 300 W at 25°C |
| Peak power | 700 W |
| System voltage | 48 V |
| Output voltage & frequency | 120 VAC, 60 Hz |
| Maximum efficiency | 90% |
Output
| Continuous power at 40°C | 260 W |
| Output AC voltage (adjustable) | 105 - 125 V |
| Output frequency (adjustable) | 50 Hz or 60 Hz ±0.1% |
| Output waveform | Pure sine wave |
Input
| Input voltage range | 36.8 - 62.0 V |
| DC low-voltage shut-down (adjustable) | 37.2 V |
| Dynamic (load-dependent) DC low shut-down | Fully configurable |
| DC low-voltage restart & alarm (adjustable) | 43.6 V |
| Battery charged detect (adjustable) | 56.0 V |
General
| Zero-load power | 8.5 W |
| Zero-load power in ECO mode | 2.6 W |
| ECO mode stop and start power setting | Adjustable |
| ECO mode minimum load | 15 W |
| Protections | Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, DC ripple too high |
| Communication port | VE.Direct (USB or Bluetooth dongle sold separately) |
| Remote on/off | Yes (two-pole connector) |
Environmental
| Operating temperature range | -40 to +65°C (derate 1.25% per °C above 40°C) |
| Cooling | Fan-assisted |
| Humidity (non-condensing) | Max 95% |
Enclosure
| Material & colour | Steel chassis, plastic cover, blue RAL 5012 |
| Battery connection | Screw terminals |
| Maximum cable cross-section | 10 mm² (AWG8) |
| Standard AC outlet socket | NEMA 5-15R (GFCI) |
| Protection category | IP21 |
| Dimensions (H x W x D) | 85 x 182 x 260 mm |
| Weight | 3.0 kg |
Standards & Certifications
| Safety | EN-IEC 60335-1, EN-IEC 62109-1, UL 458 |
| EMC | EN 55014-1, EN 55014-2, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 |
| Automotive Directive | ECE R10-4 |
No videos available for this product.