Victron
Victron MultiPlus-II 12/4000/160-32 Inverter/Charger
£1,488.00
/
Tax included.
PMP122405010
Victron MultiPlus-II 12/4000/160-32: 4000 VA continuous (3400 W at 25°C), 6000 W / 2 s peak, 160 A charger, 32 A transfer switch. PowerAssist and ESS ready.
✓
Collection or delivery in 1-2 weeks
Pickup available at Mercury Yacht Harbour
Usually ready in 2-4 days
Description
The Victron MultiPlus-II 12/4000/160-32 brings together a powerful 12 V sine wave inverter, a high-output battery charger and a fast transfer switch in one compact unit. It is one of the newer-generation MultiPlus-II models, delivering more power per kilogram and improved performance at high temperatures. PowerControl lets you cap the current drawn from a limited shore or generator supply, and PowerAssist adds inverter power in parallel with that source to handle short load peaks without overloading it, recharging the battery as soon as the load eases.
When the incoming supply fails, the unit changes over to inverter operation in less than 20 milliseconds, so connected equipment keeps running without interruption. A second AC output can shed non-essential loads automatically, and an optional external AC current sensor (50 A or 100 A) extends the PowerControl and PowerAssist range for whole-installation current sensing. Up to six units can be paralleled for higher output and three units can be configured for three-phase operation, allowing the system to scale with demand. It is compatible with Lithium, Lead-acid, Zinc-Bromine and more battery chemistries.
The MultiPlus-II is ESS ready with integrated anti-islanding for safe grid-interactive operation, and is fully configurable through VEConfigure using an MK3-USB interface. Connect it to a GX device such as a Cerbo GX and system data can be logged and viewed on the free VRM online portal, with settings changeable remotely over the internet.
PRODUCT DETAILS
- Combined 12 V inverter, 160 A charger and 32 A transfer switch in one unit
- 4000 VA continuous / 3400 W at 25°C / 6000 W / 2 s peak power
- PowerControl and PowerAssist manage and boost a limited shore or generator supply
- Under-20 ms changeover keeps connected equipment running through a supply failure
- Compatible with Lithium, Lead-acid, Zinc-Bromine and more chemistries
- Parallel and three-phase capable, up to six units in parallel
- ESS ready with built-in anti-islanding for grid-interactive systems
- GX and VRM monitoring for remote oversight and configuration
No compatible transducers listed for this product.
No spares or accessories listed for this product.
No compatible products found.
Key specifications
| System voltage | 12 V |
| Continuous output power | 4000 VA |
| Continuous output power at 25°C | 3400 W |
| Peak power | 6000 W / 2 s |
| Maximum charge current | 160 A |
| Transfer switch | 32 A |
Inverter
| DC input voltage range | 9.5 to 17 V |
| Output voltage / frequency | 230 VAC +/-2%, 50 Hz +/-0.1% |
| Cont. output power at 25°C (VA) | 4000 VA |
| Cont. output power at 25°C (W) | 3400 W |
| Cont. output power at 40°C (W) | 3100 W |
| Cont. output power at 65°C (W) | 2600 W |
| Time-limited power 1 (cold start) | 4 kW / 1 h (cold start) |
| Time-limited power 2 (cold start) | 4.5 kW / 30 min (cold start) |
| Peak power | 6000 W / 2 s |
| Maximum efficiency | 93 % |
| Zero load power | 18 W |
| Zero load power in AES mode | 11 W |
Charger
| Charge voltage 'absorption' | 14.4 V |
| Charge voltage 'float' | 13.8 V |
| Storage mode | 13.2 V |
| Maximum charge current | 160 A |
| Maximum charge current at 40°C | 150 A |
| Battery temperature sensor | Yes |
| Compatible battery chemistries | Lithium, Lead-acid, Zinc-Bromine and more |
Connectivity & control
| VE.Bus communication port | For parallel and three phase operation, remote monitoring and system integration |
| General purpose comms port | Yes, 2x |
| Programmable relay | Yes (general alarm, DC under voltage or genset start/stop) |
| Remote on/off | Yes |
| External AC current sensor (optional) | 50 A or 100 A |
Protection
| Protection | Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 VAC on inverter output, input voltage ripple too high |
Environmental
| Operating temperature range | -40 to +65 °C (fan assisted cooling) |
| Humidity (non-condensing) | Max. 95 % |
| Maximum altitude | 4000 m (1%/100 m derating above 2000 m) |
Physical
| Material & colour | Steel, blue RAL 5012 |
| Protection category | IP21 |
| Battery connection | Four M8 bolts |
| 230 VAC connection | Screw terminals 13 mm² (6 AWG) |
| Weight | 22 kg |
| Dimensions (h x w x d) | 576 x 276 x 164 mm |
Conformance
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
| Emission / Immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1/-6-2/-6-3 |
No downloads available for this product.
How fast does the MultiPlus-II switch to battery power during a grid failure?
The transfer to inverter operation happens in less than 20 milliseconds, so computers and other electronic equipment continue to operate without disruption.
What do PowerControl and PowerAssist do?
PowerControl lets you set a maximum shore or generator current; the unit then uses only the spare capacity for battery charging to avoid overloading the source. PowerAssist goes further by adding battery power to support the supply during short peaks, then recharges the battery when the load drops.
Can the MultiPlus-II be used in parallel or three-phase systems?
Yes. Up to six units can be connected in parallel for higher output, and three units of the same model can be configured for three-phase operation, with up to six sets of three paralleled for larger systems.
Is an external current sensor required?
No, it is optional. An external AC current sensor (50 A or 100 A) can be added to extend the PowerControl and PowerAssist range and to optimise self-consumption with external current sensing.
Can the MultiPlus-II be monitored remotely?
Yes. When connected to a GX device such as a Cerbo GX, system data can be stored and viewed on the free VRM portal, and settings can be changed remotely over the internet.