Victron

Victron MultiPlus-II 24/3000/70-32 Inverter/Charger

£968.40
Tax included.
PMP242305010
The Victron MultiPlus-II 24/3000/70-32 delivers 3000 VA continuous output (2400 W at 25°C) with 5500 W peak from a 24 V battery bank. It combines a 70 A charger and a 32 A transfer switch with PowerControl and PowerAssist, and is ready for parallel, three-phase and ESS use with anti-islanding.

Collection or delivery in 1-2 weeks

Pickup available at Mercury Yacht Harbour

Usually ready in 2-4 days

Description

The Victron MultiPlus-II 24/3000/70-32 is a 24 V multifunctional inverter/charger that brings together a powerful sine wave inverter, a sophisticated 70 A battery charger and an ultra fast 32 A transfer switch in a single compact enclosure. It is built for professional marine, vehicle and off-grid installations, and is equally at home in an Energy Storage System (ESS), where its integrated anti-islanding protection allows it to work safely alongside the grid and renewable sources. Two of Victron's signature technologies, PowerControl and PowerAssist, give the unit intelligent command over limited shore or generator supplies; PowerControl caps the current drawn from the source while PowerAssist adds up to 3000 VA of stored battery power to cover short load peaks. When the incoming supply fails the MultiPlus-II takes over in less than 20 milliseconds, so sensitive electronics carry on without interruption, and an optional external AC current sensor (50 A or 100 A) can be fitted to widen the PowerControl and PowerAssist range. A second AC output handles non critical loads that should be shed when the mains disappears, and up to six units can be paralleled or arranged in three phase for larger installations. Configuration is straightforward over VEConfigure using an MK3-USB interface, while connecting the system to a GX device such as a Cerbo GX unlocks local monitoring and full remote oversight on the free VRM portal.

PRODUCT DETAILS

  • Combined 24 V inverter, 70 A battery charger and 32 A transfer switch in one unit
  • 3000 VA continuous output, 2400 W at 25°C, 5500 W peak power
  • PowerControl and PowerAssist manage limited shore and generator supplies
  • Switches to battery power in under 20 ms during a grid failure
  • Two AC outputs, the second for sheddable non-critical loads
  • Parallel and three-phase capable, up to six units for higher output
  • ESS ready with integrated anti-islanding protection
  • GX device and VRM portal monitoring for local and remote oversight

No compatible transducers listed for this product.

No spares or accessories listed for this product.

No compatible products found.

Key specifications

System voltage24 V
Continuous output power3000 VA
Continuous output power at 25°C2400 W
Peak power5500 W
Maximum charge current70 A
Transfer switch32 A

Inverter

DC input voltage range19 to 33 V
Output voltage / frequency230 VAC +/-2%, 50 Hz +/-0.1%
Cont. output power at 25°C (VA)3000 VA
Cont. output power at 25°C (W)2400 W
Cont. output power at 40°C (W)2200 W
Cont. output power at 65°C (W)1700 W
Peak power5500 W
Maximum efficiency94 %
Zero load power13 W
Zero load power in AES mode9 W

Charger

Charge voltage 'absorption'28.8 V
Charge voltage 'float'27.6 V
Storage mode26.4 V
Maximum charge current70 A
Battery temperature sensorYes

Connectivity & control

VE.Bus communication portFor parallel and three phase operation, remote monitoring and system integration
General purpose comms portYes, 2x
Programmable relayYes (general alarm, DC under voltage or genset start/stop)
Remote on/offYes
External AC current sensor (optional)50 A or 100 A

Protection

ProtectionOutput short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 VAC on inverter output, input voltage ripple too high

Environmental

Operating temperature range-40 to +65 °C (fan assisted cooling)
Humidity (non-condensing)Max. 95 %
Maximum altitude2000 m

Physical

Material & colourSteel, blue RAL 5012
Protection categoryIP22
Battery connectionM8 bolts
230 VAC connectionScrew terminals 13 mm² (6 AWG)
Weight19 kg
Dimensions (h x w x d)499 x 268 x 141 mm

Conformance

SafetyEN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
Emission / ImmunityEN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1/-6-2/-6-3

No downloads available for this product.

How fast does the MultiPlus-II switch to battery power during a grid failure?
The transfer to inverter operation happens in less than 20 milliseconds, so computers and other electronic equipment continue to operate without disruption.
What do PowerControl and PowerAssist do?
PowerControl lets you set a maximum shore or generator current; the unit then uses only the spare capacity for battery charging to avoid overloading the source. PowerAssist goes further by adding battery power to support the supply during short peaks, then recharges the battery when the load drops.
Can the MultiPlus-II be used in parallel or three-phase systems?
Yes. Up to six units can be connected in parallel for higher output, and three units of the same model can be configured for three-phase operation, with up to six sets of three paralleled for larger systems.
Is an external current sensor required?
No, it is optional. An external AC current sensor (50 A or 100 A) can be added to extend the PowerControl and PowerAssist range and to optimise self-consumption with external current sensing.
Can the MultiPlus-II be monitored remotely?
Yes. When connected to a GX device such as a Cerbo GX, system data can be stored and viewed on the free VRM portal, and settings can be changed remotely over the internet.