Description
PRODUCT DETAILS
- All-in-one 12 Vdc BMS with an internal DC busbar that cuts cabling and speeds installation
- Integrated safety contactor rated 600 A continuous, opening automatically to disconnect chargers and loads on a fault
- Manages up to 96 MGLFP120210 lithium modules from a single Master LV
- Active cell and module balancing to preserve capacity and extend battery life
- RJ45 CAN-Bus with NMEA 2000, SMA and Victron VE.CAN protocol support
- Bluetooth monitoring and control through the free MG Connect app
- Programmable I/O with allow-to-charge, allow-to-discharge, 13.5 V aux output and a generator or heater relay
- Rugged ABS enclosure, IP22 rated, 6.0 kg, operating from -20 to +50 C
No exploded diagram available for this product.
No compatible transducers listed for this product.
Key specifications
| System voltage | 12 V |
| Max continuous current | 600 A (main safety contactor) |
| Battery modules supported | Up to 96 x MGLFP120210 |
| Data connection | CAN Bus RJ45 |
| Safety contactor | Integrated, opens automatically on fault |
| IP protection | IP22 |
| Weight | 6.0 kg |
Electrical
| System voltage | 12 V |
| Supply voltage range | 8 to 15 Vdc |
| Main safety contactor current | 600 A |
| Power usage (active) | 10.3 W |
| Power usage (standby) | 63 mW |
Battery configuration
| Maximum batteries connected | 96 battery modules of type MGLFP120210 |
| Cell balancing | Active balancing on cell and module level |
Communication
| Data connection | CAN Bus RJ45 |
| Communication protocols | NMEA 2000, SMA, Victron VE.CAN |
| Bluetooth | Built-in, via the MG Connect app |
Protection & I/O
| Safety contactor | Integrated main contactor, opens automatically when a parameter exceeds the safe window |
| Pre-charge circuit | Built-in, limits inrush current at start-up |
| Allow-to-charge (relay output) | 0.8 A at 60 Vdc, potential free |
| Allow-to-charge (switched voltage) | 13.5 V / 1 A, overcurrent and short-circuit protected |
| Allow-to-discharge (relay output) | 0.8 A at 60 Vdc, potential free |
| Allow-to-discharge (switched voltage) | 13.5 V / 1 A, overcurrent and short-circuit protected |
| Auxiliary output | 13.5 V / 1 A, overcurrent and short-circuit protected |
| External status signal | 13.5 V / 140 mA, overcurrent and short-circuit protected |
| Programmable contact (relay output) | 0.8 A at 60 Vdc, potential free |
Mechanical
| Dimensions (L x W x H) | 426 x 225 x 117 mm |
| Enclosure material | ABS |
| IP protection class | IP22 |
| Weight | 6.0 kg |
| Operating temperature range | -20 to +50 C |
| Humidity | Up to 95 % (non-condensing) |
General
| Manufacturer | MG Energy Systems |
| Country of origin | Netherlands |
| Approvals | IEC-EN62619 (ES-TRIN) |
| EMC emission | EN-IEC 61000-6-3:2007/A1:2011/C11:2012 |
| EMC immunity | EN-IEC 61000-6-1:2007 |
| Low Voltage Directive | EN 60335-1:2012/AC:2014 |
| RoHS | EN 50581:2012 |
| HS code | 8537109199 |
| Shipping weight | 6.6 kg |
| Classified as dangerous goods | No |