Garmin
EmpirBus™ Connect 50v v2, 12V, 8/20, CAN, LIN, LED/Touch
Pickup available at Mercury Yacht Harbour
Usually ready in 2-4 days
Description
The EmpirBus Connect 50 v2 packs the inputs, outputs and intelligence of a digital switching system into a single compact DC module. It connects directly to 12 V DC power on M6 bolts and controls and monitors a mix of input and output channels, driving loads with positive, half-bridge and window-wiper modes and per-channel software fusing.
Inputs can be configured as digital or analogue, reading switches, sensors and frequency signals, and on-unit LED indication and touch control allow channels to be read and overridden directly, including manual override and fuse reset. This is the non-isolated 12 V variant of the Connect 50 family, communicating through galvanically isolated CAN and RS485 interfaces; unlike the standard models it is not NMEA 2000 compliant, so it is intended for installations built around the EmpirBus CAN network. Up to six Connect 50 units can share a single network.
PRODUCT DETAILS
- Compact 12 V DC module with input and output channels
- On-unit LED indication and touch control for status, override and fuse reset
- Galvanically isolated CAN and RS485 interfaces with configurable protocol
- Non-isolated variant - not NMEA 2000 compliant
- Inputs configurable as digital or analogue (voltage, resistance, multi-switch, frequency)
- Positive, half-bridge and window-wiper outputs with per-channel software fusing (1-10 A)
- 50 A total output, 9-16 V DC supply, IP65 rated -20 C to +55 C
- EmpirBus Connect 50 v2 (12 V, non-isolated, LED and touch control)
- User manual including CE/FCC declaration of conformity
- Digital Switching Terms of Use document
No exploded diagram available for this product.
No compatible transducers listed for this product.
No spares or accessories listed for this product.
No compatible products found.
Module/Switching
| Channels | Up to 11 input channels and 20 output channels |
| Input types | Any input configurable as digital (negative, positive, common line) or analogue (voltage, resistance, multi-switch); frequency input on channels 6 and 22 |
| Output types | Digital positive, half-bridge (shifting polarity) and window-wiper outputs (up to four wipers) |
| Output fuse settings | 1, 5, 8 or 10 A per channel; 4 channels with 6 A minus output |
| Analogue input range | Voltage 0-16 V (12 V models) / 0-32 V (24 V models) +/-1%; resistance 0-1500 ohm +/-5% |
| Signal drive output | Up to 50 mA positive/negative |
| LED indication and touch control | Yes (on LED/touch models) |
Electrical
| Supply voltage | 9-16 V DC (12 V) |
| Maximum current | 50 A total output |
| Power consumption (power save) | 1.5 mA |
Connectivity
| Communication | Galvanically isolated CAN and RS485 (non-isolated DC module, not NMEA 2000 compliant) |
| NMEA 2000 compliant | No |
| NMEA 2000 connector | Micro 5-pin M12 male |
| Channel connectors | Molex MX150L 16-circuit (accepts up to 2.5 mm2 cable) |
| Power connection | M6 bolts |
Physical
| Dimensions | 229 x 106 x 41 mm |
| Weight | 0.4 kg |
Environmental
| Water rating | IP65 (polycarbonate, dry) |
| Operating temperature | -20 C to +55 C |
General
| System | EmpirBus digital switching (max 6 Connect-50 per network) |