Maretron
SMOKE/HEAT DETECTOR KIT
Pickup available at Mercury Yacht Harbour
Usually ready in 2-4 days
Description
The Maretron SH-004 Photoelectric Smoke / Heat Detector Kit provides networked fire detection for general-use areas such as cabins and saloons. It is intended for dry areas and should not be used where steam or moisture is regularly present; for high-moisture spaces the SH-005 kit is the better choice.
The kit contains a photoelectric smoke detector and its mounting base along with an 8k ohm end-of-line relay for circuit supervision. It connects to a free channel of a Maretron SIM100 Switch Indicator Module, which broadcasts the detector state, a switch counter and a switch timer over the NMEA 2000 network so alarms can be viewed on any compatible display. Powering the detector separately from the network keeps it working even when the NMEA 2000 supply is off.
The detector can be ceiling or wall mounted directly or onto standard electrical boxes, and features a tamper lock. A single detector should never cover more than 900 square feet, and installation should follow ABYC and NFPA fire-detection guidelines.
PRODUCT DETAILS
- Photoelectric smoke and heat detection for general-use areas
- Connects to NMEA 2000 via a Maretron SIM100 module
- Supplied with an 8k ohm end-of-line relay for supervision
- Detector powered separately so it works if the network is off
- Ceiling, wall or electrical-box mounting with tamper lock
- Covers up to 900 square feet per detector
- Photoelectric smoke/heat detector
- Detector mounting base
- 8k ohm End-of-Line (EOL) Relay
- Manufacturer installation and warranty documentation
No exploded diagram available for this product.
No compatible transducers listed for this product.
No spares or accessories listed for this product.
No compatible products found.
General
| Detector Type | Photoelectric smoke/heat detector |
| Application | General-use dry areas |
| Interface | Single channel of a Maretron SIM100 |
| Maximum Coverage | 900 sq ft per detector |
Electrical
| Supply Voltage | 10 to 35 VDC (independent of NMEA 2000 power) |
| Circuit Supervision | 8k ohm end-of-line relay |