Maretron

Maretron MPower CBMD12 Bypass Module with CBMD12, A3720 & A3721

£185.00
Tax included. Shipping calculated at checkout.
CBMD12-R
The Maretron MPower CBMD12 is a 12-channel bypass module that provides manual override for a CLMD12 DC load controller. If the controller or NMEA 2000 network fails, twelve Carling Curvette rocker switches let you power each load directly, with standard fuses for overcurrent protection. It matches the CLMD12 capacity at 75 amps for 12 and 24 volt systems.

Collection or delivery in 1-2 weeks

Pickup available at Mercury Yacht Harbour

Usually ready in 2-4 days

Description

The Maretron MPower CBMD12 12-Channel Bypass Module is installed alongside a CLMD12 DC load controller to provide a dependable manual backup. In the event of a CLMD12 malfunction or an NMEA 2000 network failure, the CBMD12 lets you continue to control every load by hand, keeping essential circuits available.

It works by providing direct power to each CLMD12 load through a dedicated physical switch. Twelve Carling Curvette rocker switches give arc-free manual control of each circuit, and standard fuses provide overcurrent protection, supplied as a fuse pack containing four 5 amp, seven 10 amp and three 15 amp fuses. The module matches the CLMD12 output arrangement of two 12 amp, six 10 amp and four 5 amp circuits, for a total capacity of 75 amps in both 12 and 24 volt DC systems.

Because each circuit is controlled by its own switch, the bypass module does not support paralleled outputs or dimming, but it delivers straightforward, reliable manual operation when it is needed most.

PRODUCT DETAILS

  • Manual bypass module for the CLMD12 DC load controller
  • Maintains control of loads if the controller or network fails
  • Twelve Carling Curvette rocker switches for arc-free manual control
  • Standard fuses for overcurrent protection (fuse pack included)
  • 75 amp total capacity (2x12A, 6x10A, 4x5A) for 12 and 24V systems
  • Direct-wired backup path independent of NMEA 2000

No exploded diagram available for this product.

No compatible transducers listed for this product.

Specifications

Number of Channels12
Maximum Current Capacity75 amps (12V and 24V DC systems)
Channel Outputs2x12A, 6x10A, 4x5A
Switches12 Carling Curvette rocker switches
Overcurrent ProtectionStandard fuses (4x 5A, 7x 10A, 3x 15A supplied)

Mechanical

Mounting3 mounting holes for #8 pan-head screws

No videos available for this product.

No downloads available for this product.

What is the CBMD12 for?
It is a manual bypass module installed alongside a CLMD12 DC load controller. If the CLMD12 malfunctions or the NMEA 2000 network fails, the CBMD12 lets you power and control each load directly using physical rocker switches.
How are loads switched on the CBMD12?
Each load is controlled by its own Carling Curvette rocker switch, which provides arc-free manual operation. Standard fuses give overcurrent protection.
Does the CBMD12 support dimming or paralleled outputs?
No. Because each circuit is controlled by a separate switch, the bypass module does not support dimming or paralleled outputs, only direct manual on/off control.