Energy Solutions
IsoBoost3 24 kVA/100A hull isolation transformer (US Spec)
£11,376.00
/
Tax included.
Shipping calculated at checkout.
IB3-24KVA-208/240-US
24kVA/100A US-spec hull isolation transformer that prevents galvanic corrosion and boosts weak or 208V shore power supplies.
✓
Collection or delivery in 1-2 weeks
Pickup available at Mercury Yacht Harbour
Usually ready in 2-4 days
Description
The Energy Solutions IsoBoost3 is a hull isolation transformer that protects your vessel from galvanic corrosion while safely delivering shore power to the onboard electrical system. It breaks the earth connection on the incoming shore supply and induces power onto a fully isolated secondary winding, so there is no direct electrical connection between the dock cable and the boat wiring. Built as a double wound transformer to BS EN 60076-1, it carries a protective screen between the input and output windings and soft starts automatically to stop inrush current tripping the marina supply breaker.
A boost function manages the volt drop found on long or heavily loaded shore lines and copes with lower or 208V (phase to phase) supplies. When the input is in range the unit runs in 1:1 mode so the output matches the input, and if the voltage falls below the boost threshold it automatically switches into boost mode to raise the output, returning to 1:1 when the supply recovers. A built in digital power meter with Modbus communication monitors voltage, frequency, current, power factor, energy use, harmonics and alarms, with an optional remote display, and the IsoBoost3 is a fit and form replacement for Charles Industries IsoBoost transformers.
PRODUCT DETAILS
- 24 kVA / 100 A US-spec hull isolation transformer, parallel operation capable
- Prevents galvanic corrosion by isolating the shore earth from the vessel
- Automatic boost mode compensates for volt drop and low or 208V shore supplies
- Double wound to BS EN 60076-1 with a screened primary and secondary
- Automatic soft start prevents inrush tripping the marina breaker
- Built in digital power meter with Modbus RTU and optional remote display
- Powder coated RAL9016 traffic white custom enclosure
- Fit and form replacement for Charles Industries IsoBoost transformers
No exploded diagram available for this product.
No compatible transducers listed for this product.
No spares or accessories listed for this product.
No compatible products found.
Key specifications
| Type | Hull isolation transformer with boost |
| Rated capacity | 24 kVA |
| Rated current | 100 A |
| Specification | US (208/240V) |
Electrical
| Input voltage | 208V / 240V nominal, automatic select |
| Output voltage | 240V / 120V (centre tap available) |
| Frequency | 50/60Hz (dual frequency, no conversion) |
| Boost mode | Raises output about 15% when input falls below 220V |
| Isolation | Double wound to BS EN 60076-1, screened windings |
| Metering | Digital power meter with Modbus RTU |
| Parallel operation | Capable |
Physical & mechanical
| Weight | 185 kg |
| Enclosure | Powder coated steel, RAL9016 traffic white |
| Input wiring | 3 wire (earth and two conductors) |
| Output wiring | 3 wire or 4 wire options |
General
| Compatibility | Fit and form replacement for Charles Industries IsoBoost |
| Country of origin | United Kingdom |
No videos available for this product.
What does an isolation transformer do for my boat?
It breaks the earth connection between the marina shore supply and your vessel, removing the galvanic loop that causes accelerated corrosion of the hull, anodes and underwater fittings. The transformer induces power onto a fully isolated secondary winding, so shore power reaches the boat with no direct electrical connection to the dock earth.
What is the boost function and when does it operate?
The IsoBoost3 normally runs in 1:1 mode so the output matches the input voltage. If the incoming shore voltage drops, for example on a long or heavily loaded shore line or a 208V phase to phase supply, the unit automatically switches into boost mode to raise the output, then returns to 1:1 when the supply recovers. This helps keep onboard equipment running correctly on weak dock supplies.
Can the IsoBoost3 replace a Charles Industries IsoBoost transformer?
Yes. The IsoBoost3 is designed as a fit and form replacement for Charles Industries IsoBoost transformers, so it suits vessels originally specified with that unit. Choose the US or Euro specification and kVA rating to match your shore supply and switchboard.