Oceanic Systems
Whistle Operating Module
£606.00
/
Tax included.
Shipping calculated at checkout.
5980
NMEA2000 module for automatic whistle and warning light signalling to IMO Rules 34 and 35, with four 1 Amp relays.
✓
Available for collection or delivery in ~2 days
Pickup available at Mercury Yacht Harbour
Usually ready in 2-4 days
Description
The Oceanic Systems 5980 Whistle Operating Module provides fully automatic control of a vessel's whistles and warning lights, activated from any Poseidon display. It generates the general manoeuvring signals for turning to starboard, turning to port, going astern and the danger signal to IMO Rule 34, and the reduced-visibility signals for a power vessel, a power vessel stopped, a vessel anchored, towed or not under command to IMO Rule 35 with variable repeat times. An immediate horn control is also available directly from any touchscreen on the vessel.
The module has two horn control relays and two warning light control relays, each fully isolated with normally open contacts and its own green indicating LED, and each relay can switch 1 Amp to drive the circuit or a larger external relay. It is DIN rail mounted with WAGO cage clamp connections and works on 12 or 24 Volt systems.
PRODUCT DETAILS
- Automatic whistle and warning light control
- General manoeuvring signals to IMO Rule 34
- Reduced-visibility signals to IMO Rule 35
- Instant horn control from any Poseidon display
- Two horn and two warning light relays
- 1 Amp switching on each of four circuits
- DIN rail mounting with WAGO connections
- 12 or 24 Volt operation
No exploded diagram available for this product.
No compatible transducers listed for this product.
No spares or accessories listed for this product.
No compatible products found.
Key specifications
| Function | Automatic whistle and warning light signalling |
| Signalling | IMO Rule 34 and Rule 35 with variable repeat |
| Relays | 2 horn and 2 warning light, fully isolated NO |
| Relay rating | 1 Amp at 35 V DC resistive per circuit |
Electrical
| Operating voltage | 9 to 32 Volts |
| Power consumption | 300 mA average operating |
| Load equivalence number | 1 |
Connection
| Terminals | WAGO cage clamp 0.08 to 2.5 mm2 |
Physical
| Size | 117 x 60 x 70 mm |
| Weight | 0.1 kg |
| Mounting | DIN rail |
Environmental
| Degree of protection | IP40 |
No videos available for this product.
What signals can it sound?
It produces the general manoeuvring signals to IMO Rule 34 (starboard, port, astern and danger) and the reduced-visibility signals to IMO Rule 35, and it can sound an immediate horn from any Poseidon touchscreen.
How many relays does it have?
Four fully isolated relays: two for horns and two for warning lights, each switching 1 Amp, which can drive the circuit directly or a larger external relay.
How is it mounted?
It is DIN rail mounted in a protected area such as an electrical cabinet, with WAGO cage clamp connections, and works on 12 or 24 Volt systems.