Victron
Victron MultiPlus-II 48/5000/70-50 Inverter/Charger
Pickup available at Mercury Yacht Harbour
Usually ready in 2-4 days
Description
PRODUCT DETAILS
- Combined 48 V inverter, 70 A battery charger and 50 A transfer switch in one unit
- 5000 VA continuous output, 4000 W at 25°C, 9000 W peak power
- PowerControl and PowerAssist manage limited shore and generator supplies
- Switches to battery power in under 20 ms during a grid failure
- Two AC outputs, the second for sheddable non-critical loads
- Parallel and three-phase capable, up to six units for higher output
- ESS ready with integrated anti-islanding protection
- GX device and VRM portal monitoring for local and remote oversight
No exploded diagram available for this product.
No compatible transducers listed for this product.
Key specifications
| System voltage | 48 V |
| Continuous output power | 5000 VA |
| Continuous output power at 25°C | 4000 W |
| Peak power | 9000 W |
| Maximum charge current | 70 A |
| Transfer switch | 50 A |
Inverter
| DC input voltage range | 38 to 66 V |
| Output voltage / frequency | 230 VAC +/-2%, 50 Hz +/-0.1% |
| Cont. output power at 25°C (VA) | 5000 VA |
| Cont. output power at 25°C (W) | 4000 W |
| Cont. output power at 40°C (W) | 3700 W |
| Cont. output power at 65°C (W) | 3000 W |
| Peak power | 9000 W |
| Maximum efficiency | 96 % |
| Zero load power | 18 W |
| Zero load power in AES mode | 12 W |
Charger
| Charge voltage 'absorption' | 57.6 V |
| Charge voltage 'float' | 55.2 V |
| Storage mode | 52.8 V |
| Maximum charge current | 70 A |
| Battery temperature sensor | Yes |
Connectivity & control
| VE.Bus communication port | For parallel and three phase operation, remote monitoring and system integration |
| General purpose comms port | Yes, 2x |
| Programmable relay | Yes (general alarm, DC under voltage or genset start/stop) |
| Remote on/off | Yes |
| External AC current sensor (optional) | 50 A or 100 A |
Protection
| Protection | Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 VAC on inverter output, input voltage ripple too high |
Environmental
| Operating temperature range | -40 to +65 °C (fan assisted cooling) |
| Humidity (non-condensing) | Max. 95 % |
| Maximum altitude | 2000 m |
Physical
| Material & colour | Steel, blue RAL 5012 |
| Protection category | IP22 |
| Battery connection | M8 bolts |
| 230 VAC connection | Bolts M6 |
| Weight | 30 kg |
| Dimensions (h x w x d) | 565 x 320 x 149 mm |
Conformance
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
| Emission / Immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1/-6-2/-6-3 |














