Victron
Victron MultiPlus-II 12/4000/160-32 Inverter/Charger
Pickup available at Mercury Yacht Harbour
Usually ready in 2-4 days
Description
PRODUCT DETAILS
- Combined 12 V inverter, 160 A charger and 32 A transfer switch in one unit
- 4000 VA continuous / 3400 W at 25°C / 6000 W / 2 s peak power
- PowerControl and PowerAssist manage and boost a limited shore or generator supply
- Under-20 ms changeover keeps connected equipment running through a supply failure
- Compatible with Lithium, Lead-acid, Zinc-Bromine and more chemistries
- Parallel and three-phase capable, up to six units in parallel
- ESS ready with built-in anti-islanding for grid-interactive systems
- GX and VRM monitoring for remote oversight and configuration
No exploded diagram available for this product.
No compatible transducers listed for this product.

Victron Cerbo GX MK2

Victron GX Touch 50 Display

Victron GX Touch 70 Display

Victron Ekrano GX

Victron SmartShunt IP65 500A Battery Monitor

Victron SmartShunt IP65 1000A Battery Monitor

Victron Lynx Smart BMS 500 (M8)

Victron Lynx Smart BMS 1000 (M10)

Victron Lithium Battery Smart 12.8V/50Ah

Victron Lithium Battery Smart 12.8V/100Ah

Victron Lithium Battery Smart 12.8V/160Ah

Victron Lithium Battery Smart 12.8V/180Ah

Victron Lithium Battery Smart 12.8V/200Ah
Key specifications
| System voltage | 12 V |
| Continuous output power | 4000 VA |
| Continuous output power at 25°C | 3400 W |
| Peak power | 6000 W / 2 s |
| Maximum charge current | 160 A |
| Transfer switch | 32 A |
Inverter
| DC input voltage range | 9.5 to 17 V |
| Output voltage / frequency | 230 VAC +/-2%, 50 Hz +/-0.1% |
| Cont. output power at 25°C (VA) | 4000 VA |
| Cont. output power at 25°C (W) | 3400 W |
| Cont. output power at 40°C (W) | 3100 W |
| Cont. output power at 65°C (W) | 2600 W |
| Time-limited power 1 (cold start) | 4 kW / 1 h (cold start) |
| Time-limited power 2 (cold start) | 4.5 kW / 30 min (cold start) |
| Peak power | 6000 W / 2 s |
| Maximum efficiency | 93 % |
| Zero load power | 18 W |
| Zero load power in AES mode | 11 W |
Charger
| Charge voltage 'absorption' | 14.4 V |
| Charge voltage 'float' | 13.8 V |
| Storage mode | 13.2 V |
| Maximum charge current | 160 A |
| Maximum charge current at 40°C | 150 A |
| Battery temperature sensor | Yes |
| Compatible battery chemistries | Lithium, Lead-acid, Zinc-Bromine and more |
Connectivity & control
| VE.Bus communication port | For parallel and three phase operation, remote monitoring and system integration |
| General purpose comms port | Yes, 2x |
| Programmable relay | Yes (general alarm, DC under voltage or genset start/stop) |
| Remote on/off | Yes |
| External AC current sensor (optional) | 50 A or 100 A |
Protection
| Protection | Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 VAC on inverter output, input voltage ripple too high |
Environmental
| Operating temperature range | -40 to +65 °C (fan assisted cooling) |
| Humidity (non-condensing) | Max. 95 % |
| Maximum altitude | 4000 m (1%/100 m derating above 2000 m) |
Physical
| Material & colour | Steel, blue RAL 5012 |
| Protection category | IP21 |
| Battery connection | Four M8 bolts |
| 230 VAC connection | Screw terminals 13 mm² (6 AWG) |
| Weight | 22 kg |
| Dimensions (h x w x d) | 576 x 276 x 164 mm |
Conformance
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
| Emission / Immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1/-6-2/-6-3 |